No. Name Unit Default Settings
Model CIMR-Po
5A0125 5A0145 5A0192 5A0242
o2-04 Drive Model Selection Hex. D5 D6 D7 D9
E2-11 Motor Rated Power kW (HP)
90
(125)
110
(150)
160
(200)
185
(250)
b3-04 V/f Gain during Speed Search % 80 80 80 80
b3-06 Output Current 1 during Speed Search 0.5 0.5 0.5 0.5
b3-07
Output Current 2 during Speed Search
(Speed Estimation Type)
b3-26 Start Speed Search Select
b8-03 Energy Saving Control Filter Time Constant s 2.00 2.00 2.00 2.00
b8-04 Energy Saving Coefficient Value 61.50 58.67 49.90 42.90
C5-17 Motor Inertia
kgm
2
1.10 1.90 2.10 4.10
C6-02 Carrier Frequency Selection 7 7 7 7
E2-01 Motor Rated Current A 125 145 192 242
E2-02 Motor Rated Slip Hz 1.39 1.40 1.35 1.35
E2-03 Motor No-Load Current A 37.5 43.2 57.6 57.6
E2-05 Motor Line-to-Line Resistance Ω 0.079 0.060 0.037 0.037
E2-06 Motor Leakage Inductance % 20.0 20.0 20.0 20.0
E2-10 Motor Iron Loss for Torque Compensation W 2150 2150 2850 2850
L2-02 Momentary Power Loss Ride-Thru Time s 2.0 2.0 2.0 2.0
L2-03 Momentary Power Loss Minimum Baseblock Time s 2.0 2.0 2.0 2.0
L2-04 Momentary Power Loss Voltage Recovery Time s 1.7 1.8 2.0 2.0
L3-24 Motor Acceleration Time for Inertia Calculations s 0.592 0.646 0.673 0.864
L8-02 Overheat Alarm Level °C 110 110 110 110
L8-35 Installation Method Selection 0 0 0 0
L8-38 Carrier Frequency Reduction Selection 2 2 2 2
n1-03 Hunting Prevention Time Constant ms 30 30 30 30
B.15 Defaults by Drive Model
YASKAWA SIEP YAIP1U 01A AC Drive - P1000 Technical Manual
461