Yaskawa CIMR-PU2A0081 [390/548] The drive standard ratings are valid for installation altitudes up to 1000 m for installations from 1000 m to 3000 m the drive rated voltage and the rated output curren...

Превью страниц Страница 390 / 548
Yaskawa CIMR-PU2A0021 [390/548] The drive standard ratings are valid for installation altitudes up to 1000 m for installations from 1000 m to 3000 m the drive rated voltage and the rated output curren...
100
85
70
55
0
L8-35 = 2: IP20/NEMA Type 1 Enclosure
L8-35 = 3: External Heatsink lnstallation
L8-35 = 0: IP00/Open-Chassis Enclosure
30
-10
40
50
Drive Rating
(%)
L8-12
(Ambient temp: °C)
L8-35 = 1: Side-by-Side Mounting
Figure A.1 Ambient Temperature and Installation Method Derating
u
Altitude Derating
The
drive
standard
ratings
are
valid
for
installation altitudes up to 1000 m. For installations from 1000 m to 3000 m, the drive
rated voltage and the rated output current must be derated for 0.2% per 100 m.
A.4 Drive Derating Data
390
YASKAWA SIEP YAIP1U 01A AC Drive - P1000 Technical Manual