Yaskawa CIMR-PU2A0081 [280/548] Table 6 gives an overview of possible fault codes conditions such as overvoltages can trip faults and alarms it is important to distinguish between faults and alarms to...

Превью страниц Страница 280 / 548
Yaskawa CIMR-PU2A0360 [280/548] Table 6 gives an overview of possible fault codes conditions such as overvoltages can trip faults and alarms it is important to distinguish between faults and alarms to determine the proper corrective actions when the drive detects a fault the alm indicator led lights the fault code appears on the digital operator and the fault contact ma mb mc triggers an alarm is present if the alm led blinks and the fault code on the digital operator flashes refer to minor faults and alarms on page 281 for a list of alarm codes
u
Alarm and Error Displays
n
Faults
Table
6.4 gives an overview of possible fault codes. Conditions such as overvoltages can trip faults and alarms. It is important
to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects a fault, the ALM indicator LED lights, the fault code appears on the digital operator, and the fault
contact MA-MB-MC triggers. An alarm is present if the ALM LED blinks and the fault code on the digital operator flashes.
Refer to Minor Faults and Alarms on page 281 for a list of alarm codes.
Table 6.4 Fault Displays
Digital
Operator
Display
Name Page
bAT Digital Operator Battery Voltage Low 283
boL Braking Transistor Overload Fault 283
bUS Option Communication Error 283
CE MEMOBUS/Modbus Communication Error 283
CPF11 to
CPF14
<1> <3>
Control Circuit Error 283
CPF16 to
CPF19
<1> <3>
Control Circuit Error 283
CPF02 A/D Conversion Error 284
CPF03 Control Board Connection Error 284
CPF06
<3>
EEPROM Memory Data Error 284
CPF07,
CPF08
Terminal Board Connection Error 284
CPF20,
CPF21
<2>
Control Circuit Error 284
CPF22 Hybrid IC Error 284
CPF23 Control Board Connection Error 285
CPF24
<3>
Drive Unit Signal Fault 285
CPF25 Terminal Board Not Connected 285
CPF26 to
CPF35,
CPF40 to
CPF43
Control Circuit Error 285
E5 SI-T3 Watchdog Timer Error 285
EF0 Option Card External Fault 285
EF1 to EF8
External Fault
(input terminal S1 to S8)
285
Err EEPROM Write Error 286
FAn Internal Fan Fault 285
FbH Excessive PID Feedback 286
FbL PID Feedback Loss 287
GF Ground Fault 287
LF Output Phase Loss 287
nSE Node Setup Error 287
oC Overcurrent 287
oFA00
<3>
Option Card Connection Error
(CN5-A)
288
oFA01 Option Card Fault (CN5-A) 288
Digital
Operator
Display
Name Page
oFA03 to
oFA06
Option Card Error
(CN5-A)
288
oFA10,
oFA11
Option Card Error
(CN5-A)
288
oFA12 to
oFA17
Option Card Connection Error
(CN5-A)
288
oFA30 to
oFA43
Comm Option Card Connection Error
(CN5-A)
288
oFb00
<3>
Option Card Connection Error
(CN5-B)
289
oFb01 Option Card Fault (CN5-B) 289
oFb02 Option Card Fault (CN5-B) 289
oFb03,
oFb11
Option Card Error (CN5-B) 289
oFb12 to
oFb17
Option Card Connection Error
(CN5-B)
289
oFC00
<3>
Option Card Connection Error
(CN5-C)
289
oFC01 Option Card Fault (CN5-C) 289
oFC02 Option Card Fault (CN5-C) 290
oFC03,
oFC11
Option Card Error (CN5-C) 290
oFC12 to
oFC17
Option Card Connection Error
(CN5-C)
290
oFC50 to
oFC55
Option Card Error (CN5-C) 290
oH Heatsink Overheat 290
oH1 Heatsink Overheat 290
oH4 Motor Overheat Fault (PTC input) 301
oL1 Motor Overload 291
oL2 Drive Overload 291
oL3 Overtorque Detection 1 291
oL4 Overtorque Detection 2 292
oL7 High Slip Braking oL 292
oPr Operator Connection Fault 292
ov Overvoltage 292
PF Input Phase Loss 293
rF Braking Resistor Fault 293
rH Dynamic Braking Resistor 293
rr Dynamic Braking Transistor 294
SC IGBT Short Circuit or Ground Fault 294
SEr Too Many Speed Search Restarts 294
TdE Time Data Error 294
6.3 Drive Alarms, Faults, and Errors
280
YASKAWA SIEP YAIP1U 01A AC Drive - P1000 Technical Manual

Содержание

2656