Yaskawa CIMR-PU2A0081 — установка цифрового оператора: руководство по монтажу и креплению [50/548]

Превью страниц Страница 50 / 548
Yaskawa CIMR-PU2A0018 [50/548] Note use a gasket between the enclosure panel and the digital operator in environments with a significant amount of dust or other airborne debris
Digital Operator
M3 x 6
Phillips recessed
pan head machine screw x 2
Enclosure panel
Unit: mm
Figure 2.7 External/Face-Mount Installation
22
22
14
26
22
78
2
Unit: mm
Figure 2.8 Panel Cut-Out Dimensions (External/Face-Mount Installation)
Internal/Flush-Mount
An internal flush-mount requires an installation support set that must be purchased separately. Contact a Yaskawa
representative to order an installation support set
and mounting hardware. Figure 2.9 illustrates how to attach the Installation
Support Set A.
1.
Cut an opening in the enclosure panel for the digital operator as shown in Figure 2.10.
2.
Mount the digital operator to the installation support.
3.
Mount the installation support set and digital operator to the enclosure panel.
Enclosure panel
Unit: mm
Digital Operator
Installation Support Set A
M4 × 10
Phillips truss head screw × 4
(for panel widths between 1 and 1.6)
M3 × 6
Phillips recessed
pan head machine screw × 2
Figure 2.9 Internal/Flush Mount Installation
Note: Use
a
gasket
between
the
enclosure
panel
and the digital operator in environments with a significant amount of dust or other airborne debris.
2.2 Mechanical Installation
50
YASKAWA SIEP YAIP1U 01A AC Drive - P1000 Technical Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Содержание

2656

Подробное руководство по установке цифрового оператора, включая размеры, монтажные детали и советы по креплению. Узнайте, как правильно установить оборудование.