H1 Multi-Function Digital Input Selections
H1-oo
Setting
Function Description Page
41
Reverse run command
(2-Wire sequence)
Open: Stop
Closed: Reverse run
Note: Cannot be set together with settings 42 or 43.
203
42
Run command
(2-Wire sequence 2)
Open: Stop
Closed: Run
Note: Cannot be set together with settings 40 or 41.
203
43
FWD/REV command
(2-Wire sequence 2)
Open: Forward
Closed: Reverse
Note: Determines motor direction, but does not issue a Run command. Cannot be set
together with settings 40 or 41.
203
47 Node setup Closed: Node setup for SI-S3 enabled. 203
51
Sequence Timer Disable
SeqTimer Disable
Closed: Drive ignores sequence timers and runs normally (based on b1-02/b1-16 source). 203
52
Sequence Timer Cancel
SeqTimer Cancel
Closed: When the input changes from open to closed, the currently active sequence timer is
disabled. Operation will resume with the next scheduled sequence timer. Cycling the Run
command after the current sequence timer has been canceled will re-enable the sequence
timer.
203
60 DC Injection Braking command Closed: Triggers DC Injection Braking. 203
61
External Speed Search
command 1
Closed: Activates Current Detection Speed Search from the maximum output frequency
(E1-04).
204
62
External Speed Search
command 2
Closed: Activates Current Detection Speed Search from the frequency reference. 204
63 Field weakening Closed: The drive performs Field Weakening control as set for d6-01 and d6-02. 204
65 KEB Ride-Thru 1 (N.C.) Open: KEB Ride-Thru 1 enabled. 204
66 KEB Ride-Thru 1 (N.O.) Closed: KEB Ride-Thru 1 enabled. 204
67 Communications test mode
Tests the MEMOBUS/Modbus RS-422/RS-485 interface. Displays “PASS” if the test
completes successfully.
204
68 High Slip Braking (HSB) Closed: Activates High Slip Braking to stop the drive during a Run command. 204
6A Drive enable
Open: Drive disabled. If this input is opened during run, the drive will stop as specified by
b1-03.
Closed: Ready for operation.
204
75 Up 2 command
Used to control the bias added to the frequency reference by the Up/Down 2 function. The
Up 2 and Down 2 commands must always be used in conjunction with one another.
204
76 Down 2 command
Used to control the bias added to the frequency reference by the Up/Down 2 function. The
Up 2 and Down 2 commands must always be used in conjunction with one another.
204
7A KEB Ride-Thru 2 (N.C.)
Open: KEB Ride-Thru 2 enabled. Drive disregards L2-29 and performs Single Drive KEB
Ride-Thru 2.
205
7B KEB Ride-Thru 2 (N.O.)
Closed: KEB Ride-Thru 2 enabled. Drive disregards L2-29 and performs Single Drive KEB
Ride-Thru 2.
205
A8
Secondary PI Disable (N.O.)
PI2 Disable N.O.
Closed: Disables the secondary PI controller. Output behavior depends on the setting of
S3-12.
206
A9
Secondary PI Disable (N.C.)
PI2 Disable N.C.
Closed: Enables the secondary PI controller. Output behavior depends on the setting of S3-12
when open.
206
AA
Secondary PI Inverse Operation
PI2 Invert
Closed: Changes the sign of the secondary PI controller input (reverse acting PI control).
206
AB
Secondary PI Integral Reset
PI2 Intgrl Reset
Closed: Resets the secondary PI controller integral value.
206
AC
Secondary PI Integral Hold
PI2 Intgrl Hold
Closed: Locks the value of the secondary PI controller integral value.
206
AD
Select Secondary PI Parameters
Select PI2 Parms
Closed: Uses the secondary PI controller Proportional and Integral adjustments (S3-06 and
S3-07) instead of the primary PI controller
Proportional and Integral adjustments (b5-02 and
b5-03). Only valid when S3-01 = 0 (secondary PI controller disabled).
Note: This multi-function input has no effect on the secondary PI controller. It is only
used for the primary PI controller (b5-oo).
206
AF
Emergency Override Forward Run
EmergOverrideFWD
Closed: Run the drive forward using the speed set in S6-02.
206
B.7 H Parameters: Multi-Function Terminals
YASKAWA SIEP YAIP1U 01A AC Drive - P1000 Technical Manual