Daikin FXSQ32MVE [19/458] Model selection si34 803

Daikin FXSQ63MVE [19/458] Model selection si34 803
Model Selection Si34-803
8 General Information
4. Model Selection
VRV III Heat Pump Series
Outdoor Units
Normal Type (Space Saving Type)
High-COP Type (Energy Saving Type)
Maximum number of
connectable indoor units*
Total capacity index of
connectable indoor units*
HP Combination
RXYQ5P(A)
RXYQ8P(A)
RXYQ10P(A)
RXYQ12P(A)
RXYQ14P(A)
RXYQ16P(A)
RXYQ18P(A)
RXYQ8P(A) + RXYQ12P(A)
RXYQ10P(A) + RXYQ12P(A)
RXYQ8P(A) + RXYQ16P(A)
RXYQ8P(A) + RXYQ18P(A)
RXYQ10P(A) + RXYQ18P(A)
RXYQ12P(A) + RXYQ18P(A)
RXYQ16P(A) x 2
RXYQ16P(A) + RXYQ18P(A)
RXYQ18P(A) x 2
RXYQ8P(A) + RXYQ12P(A) + RXYQ18P(A)
RXYQ8P(A) + RXYQ16P(A) x 2
RXYQ8P(A) + RXYQ16P(A) + RXYQ18P(A)
RXYQ8P(A) + RXYQ18P(A) x 2
RXYQ10P(A) + RXYQ18P(A) x 2
RXYQ12P(A) + RXYQ18P(A) x 2
62.5 to 162.5 (250)
100 to 260 (400)
125 to 325 (500)
150 to 390 (600)
175 to 455 (700)
200 to 520 (800)
225 to 585 (900)
250 to 650 (800)
275 to 715 (880)
300 to 780 (960)
325 to 845 (1,040)
350 to 910 (1,120)
375 to 975 (1,200)
400 to 1,040 (1,280)
425 to 1,105 (1,360)
450 to 1,170 (1,440)
475 to 1,235 (1,235)
500 to 1,300 (1,300)
525 to 1,365 (1,365)
550 to 1,430 (1,430)
575 to 1,495 (1,495)
600 to 1,560 (1,560)
Model name
RXYQ5P(A)
RXYQ8P(A)
RXYQ10P(A)
RXYQ12P(A)
RXYQ14P(A)
RXYQ16P(A)
RXYQ18P(A)
RXYQ20P(A)
RXYQ22P(A)
RXYQ24P(A)
RXYQ26P(A)
RXYQ28P(A)
RXYQ30P(A)
RXYQ32P(A)
RXYQ34P(A)
RXYQ36P(A)
RXYQ38P(A)
RXYQ40P(A)
RXYQ42P(A)
RXYQ44P(A)
RXYQ46P(A)
RXYQ48P(A)
5 HP
8 HP
10 HP
12 HP
14 HP
16 HP
18 HP
20 HP
22 HP
24 HP
26 HP
28 HP
30 HP
32 HP
34 HP
36 HP
38 HP
40 HP
42 HP
44 HP
46 HP
48 HP
8 (12)
13 (20)
16 (25)
19 (30)
23 (35)
26 (40)
29 (45)
32 (40)
35 (44)
39 (48)
42 (52)
45 (56)
48 (60)
52 (64)
55 (64)
58 (64)
61 (61)
64 (64)
Outdoor unit multi
connection piping kit
BHFP22P100
BHFP22P151
RXYQ14P(A) + RXYQ18P(A) x 2
RXYQ16P(A) + RXYQ18P(A) x 2
RXYQ18P(A) x 3
625 to 1,625 (1,625)
650 to 1,690 (1,690)
675 to 1,755 (1,755)
RXYQ50P(A)
RXYQ52P(A)
RXYQ54P(A)
50 HP
52 HP
54 HP
Note:
For multiple connection of 20 HP systems and above, the above Daikin optional kit (separately sold) is required.
*Values inside brackets are based on connection of indoor units rated at maximum capacity, 200% for single outdoor units, 160%
for double outdoor units, and 130% for triple outdoor units.
Maximum number of
connectable indoor units*
Total capacity index of
connectable indoor units*
HP Combination
RXYQ8P(A) x 2 200 to 520 (640)
Model name
RXYQ16P(A)H16 HP 26 (32)
Outdoor unit multi
connection piping kit
BHFP22P100
RXYQ8P(A) + RXYQ10P(A) 225 to 585 (720)RXYQ18P(A)H18 HP 29 (36)
RXYQ8P(A) x 3 300 to 780 (780)RXYQ24P(A)H24 HP 39 (39)
RXYQ8P(A) x 2 + RXYQ10P(A) 325 to 845 (845)RXYQ26P(A)H26 HP 42 (42)
RXYQ8P(A) x 2 + RXYQ12P(A) 350 to 910 (910)RXYQ28P(A)H28 HP 45 (45)
RXYQ8P(A) + RXYQ10P(A) + RXYQ12P(A)
375 to 975 (975)RXYQ30P(A)H30 HP 48 (48)
52 (52)
55 (55)
58 (58)
RXYQ8P(A) + RXYQ12P(A) x 2 400 to 1,040 (1,040)RXYQ32P(A)H32 HP
RXYQ10P(A) + RXYQ12P(A) x 2 425 to 1,105 (1,105)RXYQ34P(A)H34 HP
BHFP22P151
RXYQ12P(A) x 3 450 to 1,170 (1,170)RXYQ36P(A)H36 HP
RXYQ12P(A) x 2 + RXYQ14P(A) 475 to 1,235 (1,235)RXYQ38P(A)H38 HP 61 (61)
RXYQ12P(A) x 2 + RXYQ16P(A) 500 to 1,300 (1,300)RXYQ40P(A)H40 HP
64 (64)
RXYQ12P(A) x 2 + RXYQ18P(A) 525 to 1,365 (1,365)RXYQ42P(A)H42 HP
RXYQ12P(A) + RXYQ16P(A) x 2 550 to 1,430 (1,430)RXYQ44P(A)H44 HP
RXYQ12P(A) + RXYQ16P(A) + RXYQ18P(A)
575 to 1,495 (1,495)RXYQ46P(A)H46 HP
RXYQ16P(A) x 3 600 to 1,560 (1,560)RXYQ48P(A)H48 HP
RXYQ16P(A) x 2 + RXYQ18P(A) 625 to 1,625 (1,625)RXYQ50P(A)H50 HP
Note:
For multiple connection of 16 HP systems and above, the above Daikin optional kit (separately sold) is required.
*Values inside brackets are based on connection of indoor units rated at maximum capacity, 200% for single outdoor units, 160%
for double outdoor units, and 130% for triple outdoor units.