Daikin FXSQ32MVE [276/458] Applicable models

Daikin FXSQ32MVE [276/458] Applicable models
Si34-803 Troubleshooting by Indication on the Remote Controller
Troubleshooting 265
Remote
Controller
Display
A6
Applicable
Models
FXMQ40~125P
Method of
Malfunction
Detection
Detection from the current flow on the fan PC board.
Detection from the RPM of the fan motor in operation.
Detection from the position signal of the fan motor.
Detection from the current flow on the fan PC board when the fan motor starting operation.
Malfunction
Decision
Conditions
An overcurrent flows.
The RPM is less than a certain level for 6 seconds.
A position error in the fan rotor continues for 5 seconds or more.
An overcurrent flows.
Supposed
Causes
The clogging of a foreign matter.
The disconnection of the fan motor connectors (X1A and X2A).
The disconnection of the connectors between the indoor PCB (A1P) and fan PC board
(A2P).
A failure in fan PC board (A2P).
A failure in the fan motor.