1.15.3 Removal of the horizontal blade and vertical blade
Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Procedure:
Step Procedure Points
1 Removing the horizontal
blade.
1 Open the horizontal
blade.
2 Bend the horizontal blade
slightly to disengage the
fixing part at right side.
3 Pull the horizontal blade
rightward and take it out.
Horizontal blade
Holder