Nissan Note — диагностика и проверка кислородного датчика: пошаговое руководство [314/1872]

Превью страниц Страница 314 / 1872
Nissan Note [314/1872] Heated oxygen sensor 1 with consult ii
EC-314
[CR (WITH EURO-OBD)]
DTC P1143 HO2S1
7. CHECK INTERMITTENT INCIDENT
Refer to EC-127, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
For circuit, refer to EC-180, "
Wiring Diagram" .
>> INSPECTION END
Component Inspection
BBS0030C
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGER POINT” to 100% in “DATA MONITOR” mode with CONSULT-
II.
3. Select “HO2S1 (B1)” and “HO2S1 MNTR (B1)”.
4. Hold engine speed at 2,000 rpm under no load during the follow-
ing steps.
5. Touch “RECORD” on CONSULT-II screen.
6. Check the following.
“HO2S1 MNTR (B1)” in “DATA MONITOR” mode changes
from “RICH” to “LEAN” to “RICH” more than 5 times in 10 sec-
onds.
5 times (cycles) are counted as shown in the figure.
“HO2S1 (B1)” voltage goes above 0.6V at least once.
“HO2S1 (B1)” voltage goes below 0.3V at least once.
“HO2S1 (B1) voltage never exceeds 1.0V.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner and approved anti-seize lubricant.
MBIB0301E
SEF217YA
SEF648Y

Содержание

9427

Узнайте, как правильно диагностировать и проверять кислородный датчик с помощью CONSULT-II. Пошаговые инструкции и советы по замене датчика для оптимальной работы двигателя.

Случайные обсуждения