Nissan Note [1316/1872] Ec 1316

Nissan Note [1316/1872] Ec 1316
EC-1316
[HR (WITHOUT EURO-OBD)]
TROUBLE DIAGNOSIS
LOAD SIGNAL
[ON/OFF]
××
Indicates [ON/OFF] condition from the electri-
cal load signal.
ON: Rear window defogger switch is ON and/
or lighting switch is in 2nd position.
OFF: Both rear window defogger switch and
lighting switch are OFF.
IGNITION SW
[ON/OFF]
×
Indicates [ON/OFF] condition from ignition
switch.
HEATER FAN SW
[ON/OFF]
×
Indicates [ON/OFF] condition from the heater
fan switch signal.
BRAKE SW
[ON/OFF]
×
Indicates [ON/OFF] condition from the stop
lamp switch signal.
INJ PULSE-B1
[msec]
×
Indicates the actual fuel injection pulse width
compensated by ECM according to the input
signals.
When the engine is stopped, a
certain computed value is indi-
cated.
IGN TIMING [BTDC] ×
Indicates the ignition timing computed by ECM
according to the input signals.
When the engine is stopped, a
certain value is indicated.
PURG VOL C/V [%]
Indicates the EVAP canister purge volume
control solenoid valve control value computed
by the ECM according to the input signals.
The opening becomes larger as the value
increases.
INT/V TIM (B1)
[°CA]
Indicates [°CA] of intake camshaft advanced
angle.
INT/V SOL (B1) [%]
The control value of the intake valve timing
control solenoid valve (determined by ECM
according to the input signal) is indicated.
The advance angle becomes larger as the
value increases
AIR COND RLY
[ON/OFF]
×
The air conditioner relay control condition
(determined by ECM according to the input
signals) is indicated.
FUEL PUMP RLY
[ON/OFF]
×
Indicates the fuel pump relay control condition
determined by ECM according to the input sig-
nals.
THRTL RELAY
[ON/OFF]
×
Indicates the throttle control motor relay con-
trol condition determined by the ECM accord-
ing to the input signals.
COOLING FAN
[HI/LOW/OFF]
Indicates the condition of the cooling fan
(determined by ECM according to the input
signals).
HI: High speed operation
LOW: Low speed operation
OFF: Stop
HO2S1 HTR (B1)
[ON/OFF]
Indicates [ON/OFF] condition of heated oxy-
gen sensor 1 heater determined by ECM
according to the input signals.
HO2S2 HTR (B1)
[ON/OFF]
Indicates [ON/OFF] condition of heated oxy-
gen sensor 2 heater determined by ECM
according to the input signals.
Monitored item
[Unit]
ECM
INPUT
SIGNALS
MAIN
SIG-
NALS
Description Remarks

Содержание