D-Link DES-2108/E [189/199] Notes about the configuration file

D-Link DES-2108/E [189/199] Notes about the configuration file
24-port NWay Ethernet Switch User’s Guide
Sample Configuration File 175
For example, ‘‘
e:\3225\3225prom.tfp
’. Make sure double-
quotes are used as in the example file below.
Ip_addr
--- this is the IP address that will be assigned to the
switch. This command is included for downloading a
configuration settings file to another switch. The IP address
defined in this file will override the IP address in the
configuration settings file, thus the switch you are downloading
to can have a different IP address than the one that created the
configuration settings file. An example IP address is
10.12.19.102
.
Subnet_mask
--- this is the subnet mask that will be assigned
to the switch. An example subnet mask is
255.128.0.0
.
Default_gateway
--- this is the default gateway IP that will
be assigned to the switch. An example default Gateway IP is
10.254.254.253
.
# --- Remark. When placed as the first character on a line, the
entire line will be ignored by the switch. This allows items to be
labeled, or unused commands to remain in the file so that the
syntax will not be forgotten.
Notes about the Configuration File:
This configuration file can only contain 4 settings:
Code_type,
Ip_addr,
Subnet_mask
and
Default_gateway
.
Each command can only appear once in the configuration file.
If both the Firmware Update and Use Configuration file options
are enabled, the Firmware Update command will take precedence
and only the firmware file will be uploaded to the switch.