Daikin RXYQ16M7W1B [81/344] Heating oil return defrost operation

Daikin RXYQ16M7W1B [81/344] Heating oil return defrost operation
Refrigerant Flow for Each Operation Mode SiE39-404
70 Refirgerant Circuit
Heating Oil Return & Defrost Operation
4D044809
Fan OFFFan OFF
Indoor unit
Indoor unit Indoor unit
Fan OFF
Thermostat "ON" Thermostat "OFF"
" OFF " " ON "" ON "
High temperature, high pressure gas
High temperature, high pressure liquid
Low temperature, low pressure
Indoor unit operation
Heat exchanger Heat exchanger Heat exchanger
FanFanFan
Filter Filter Filter Filter Filter Filter
S
Oil equalizing pipe to other outdoor units
Liquid piping to other outdoor units
Gas piping to other outdoor units
S
S
EXV : 512 pls EXV : 512 pls EXV : 512 pls
Solenoid
valve
Solenoid
valve
Solenoid
valve
Low pressure
sensor
Stop valve (With service port on on-site piping side ø7.9mm flare connection)
Receiver
Filter
Filter
Filter
Oil
separator
Oil
separator
Oil
separator
Filter
Filter
Filter
Filter
Filter
Filter
Filter
Filter
Filter
Filter
Filter
Capillary tube
Capillary tube
Fan
Heat
exchanger pipe
Heat exchanger
Pressure
regulating
valve
Check
valve
Check
valve
Check
valve
Check
valve
Check
valve
Check valve
Check
valve
Check
valve
Solenoid
valve
Four way
valve
Pressure
regulating
valve
High pressure
switch
High pressure
switch
High pressure
sensor
High pressure
s
witch
Capillary
tube
Capillary
tube
Capillary
tube
STD2
Compressor
STD1
Compressor
INV
Compressor
Electronic
expansion valve
Electronic
expansion
valve