Daikin RZQ125B7W1B [168/326] 20 part 3 troubleshooting

Daikin RZQ100B8V3B [168/326] 20 part 3 troubleshooting
Troubleshooting ESIE05-03
3–20 Part 3 Troubleshooting
3
1
3
4
5
Troubleshooting
Caution Be sure to turn off power switch before connect or disconnect connector, or parts damage may be
occurred.
Continuous
slight noise of "shoo..."
during cooling or
defrosting
Creak
during heating
and after operation
stop
Sound of
"shoo..." generates
during cooling or after
operation
stop.
Sound of
"shoo..." generates
just after operation start
or stop, or defrosting
start or
stop.
Excess charge of refrigerant
Air intrudes into refrigerant
system
Flushing noise due to
refrigerant shortage.
(Sound of shoo...)
Does
the noise
generate with vibration
of unit mounting
section?
Does
the noise generate
with vibration of whole
ceilings and
walls?
Is the piping secured?
Does
the fan contact with other
parts?
Does
the pipe contact with
casing?
Is the
noise flushing
sound from pressure
reducing valve or
capillary
tube?
Correction of installation
Reinforcement for ceilings or
walls
Insert shock absorber in
mounting section, or strengthen
the mounting section.
Normal. The sound is flushing
noise of gas (refrigerant) inside
air conditioning unit
Insert cushion materials to the
pipe support such as saddle.
Normal. The noise is a sound
generated at the time of gas
(refrigerant) flow change or stop
Disassemble and remove parts
contact.
Normal. Operation sound of
draining device
Correct piping manually or
attach a dead weight to pipe
Normal. Creak generates by
shrinkage of resin parts due to
temperature change.
Normal.
After vacuum drying, charge
correct amount of refrigerant.
NO
YES
YES
YES
YES
YES
YES
NO
NO
NO
YES
[Power supply side]
NO
NO
NO
NO
YES
NO
YES
YES
NO
YES
[Installation work side]
(S1997)
ESIE05-03.book Page 20 Wednesday, April 6, 2005 4:09 PM