Daikin RZQ125B7W1B [230/326] Electronic thermal time lag l8

Daikin RZQ125B7W1B [230/326] Electronic thermal time lag l8
Error Codes: Outdoor Units ESIE05-03
3–82 Part 3 Troubleshooting
3
1
3
4
5
3.16 Electronic Thermal (Time Lag) (L8)
Remote Controller
Display
L8
Method of
Malfunction
Detection
Malfunction is detected by converting the current flowing to power transistor into voltage with CT1 (DC
current sensor).
Inverter PC board detects the disorder of position signal.
Malfunction
Decision
Conditions
When compressor overload (except for when startup) is detected.
Supposed Causes
P Compressor overload (during operation)
P Disconnected compressor coil
P Faulty inverter
P Faulty compressor (if bearing is scratched)
ESIE05-03.book Page 82 Wednesday, April 6, 2005 4:09 PM