Icom IC-2820H [88/164] Memory mode operation

Icom IC-2820H [88/164] Memory mode operation
67
6
MEMORY MODE OPERATION
[EXAMPLE]: Programming the bank name “AIR” into the scan edge channel 3A.
Enter “I” and “R” with (Main
band’s) and (Left band’s), then
push (Right band’s) to select
memory write mode.
V/MHz
SCAN
M/CALL
MW
Push and hold (Left band’s) for 1 sec. to program.
M/CALL
MW
Push (Main band’s) to select memory mode.
Rotate (Main band’s) to
select “A”, then push .
M/CALL
MW
Push and hold (Main band’s) for 1 sec.
to enter select memory write condition.
Push (Main band’s) several times
to select “B NAME”.
Push (Right band’s) to enter bank
name edit mode.
*Select “M NAME” or “S NAME” when programing the memory name or the
scan name, respectively.
Bank name edit mode
Select memory write mode
Memory mode
SEL
EDIT
M/CALL
MW
>
Rotate (Main band’s) to select scan edge
channel 3A.
M
A
I
N
B
A
N
D
M
A
I
N
B
A
N
D
M
A
I
N
B
A
N
D
M/CALL
MW
>
V/MHz
SCAN
BACK
M/CALL
MW
S.MW
DD
To indicate the channel name
The channel name indication can be set independently for
each memory channel.
qSelect the desired memory channel in the main band.
Push the same band’s [M/CALL•MW] several times to
select memory mode, then rotate the same band’s [DIAL]
to select the desired memory channel.
•“X” and memory channel number appear.
wPush [F•]to display the function guide.
ePush [M.N](LOW•PRIO) several times to select “MEMORY
NAME,” “FREQUENCY” or OFF.
When “MEMORY NAME” is selected, the programmed memory
name is indicated above frequency indication; when “FRE-
QUENCY” is selected, the programmed memory name is indi-
cated at the frequency indication and the programmed frequency
is indicated above the memory name.
rPush [F•]twice to exit the function guide indication.
NOTE: When no memory name is programmed, the stored
frequency is displayed.