Yamaha TT600RE (2004) [104/382] Insp adj

Yamaha TT600RE (2004) [104/382] Insp adj
CHECKING AND CHARGING THE BATTERY
3-50
INSP
ADJ
Charging method using a variable-current (voltage) type charger
Charger
NOTE:
Voltage should be measured 30 minutes
after the machine is stopped.
NOTE:
Set the charging voltage at 16 ~ 17 V (if
the setting is lower, charging will be
insufficient. If too high, the battery will be
over-charged.)
AMP
meter
Measure the open-circuit
voltage prior to charging.
Connect a charger and AMP
meter to the battery and start
charging.
Make sure the current is
higher than the standard
charging current written on
the battery.
By turning the charging voltage
adjust dial, set the charging
voltage at 20 ~ 25 V.
Monitor the amperage for 3 ~ 5
minutes to check if the standard
charging current is reached.
Adjust the voltage so that
current is at standard charg-
ing level.
Set the timer according to
the charging time suitable for
the open-circuit voltage.
Refer to "Battery condition
checking steps."
If the current does
not exceed standard
charging current af-
ter 5 minutes, re-
place the battery.
In case that charging requires more than 5 hours, it is advisable to check
the charging current after a lapse of 5 hours.
If there is any charge in the amperage, readjust the voltage to obtain the
standard charging current.
Measure the battery open-circuit voltage after having left the battery un-
used for more than 30 minutes.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.