D-Link DWC-1000 [141/368] Auto rollover using option port

D-Link DWC-1000 [141/368] Auto rollover using option port
D-Link DWC-1000 User Manual 141
Section 5 - Advanced Network Conguration
Auto-Rollover using Option Port
InthismodeoneofyourOptionportsisassignedasthe primaryInternetlinkforallInternettracandthe
secondary Option port is used for redundancy in case the primary link goes down for any reason. Both Option
ports(primaryandsecondary)mustbeconguredtoconnecttotherespectiveISPsbeforeenablingthisfeature.
ThesecondaryOptionportwillremainunconnecteduntilafailureisdetectedontheprimarylink(eitherport
canbeassignedastheprimary).Intheeventofafailureontheprimaryport,allInternettracwillberolled
over to the backup port. When congured in Auto-Failover mode, the link status of the primary Option port is
checked at regular intervals as dened by the failure detection settings.
1. Click Network > Internet > Option Mode.
Field Description
Option Mode Select Auto-Rollover Using Option Port from the drop-down menu.
Use Primary Port Select which Option port is the primary.
Use Secondary Option
Port
Select which port to use if the primary port fails.
DNS Lookup Method
• Option DNS Servers: DNS Lookup of the DNS Servers of the primary link is used to detect primary
Option connectivity.
• DNS Servers: DNS Lookup of the custom DNS Servers can be specied to check the connectivity of
the primary link.
• Ping these IP addresses:TheseIPswillbepingedatregularintervalstochecktheconnectivityof
the primary link.
• Retry Interval is: The number tells the controller how often it should run the above congured
failure detection method.
• Failover after: This sets the number of retries after which failover is initiated.
Option 1/Option 2 EntertheDNSserverorIPaddresstoping.
Retry Interval EnterthetimeinsecondstoinitiatetheWANhealthcheck.Defaultisevery30seconds.
Failover After Enterthenumberoffailuresbeforethecontrollerwillenablethefailoverprocess.
2. Complete the elds from the table below and click Save.