1.14 Electrical Specifications for options: EWAQ130-150DAYN
Electrical
specifications
The table below contains the electrical specifications for the options of the EWAQ130-150DAYN.
Electrical specifications options
OPSP
Units EWAQ130DAYN* EWAQ150DAYN*
Std Pump Starting method Direct On-Line
Power W 3 kW 3 kW
Maximum Running current A 6,3 6,3
Starting current A 58 58
OPHP
Units EWAQ130DAYN* EWAQ150DAYN*
High Esp Pump Starting method Direct On-Line
Power W 5,5 kW 5,5 kW
Maximum Running current A 11,2 11,2
Starting current A 131 131
OP 10
Units EWAQ130DAYN* EWAQ150DAYN*
Heater Tape Supply Voltage V 230+/-10%
Recommended fuses A 2x 10 A
Power standard model 1 x 300W 1 x 300W
Power model with pump 2 x 300W 2 x 300W
Power model with pump and buffer
tank
2 x 300W + 1 x 150W 2 x 300W + 1 x 150W