ethernet cfm ma <ma-index> format
<vid|string|integer> name <ma-name>
md <md-index> primary-vlan <1-4094>
Creates an MA (Maintenance Association) and defines
its VLAN ID under the MD. You can also define the
format which the Switch uses to send this MA information
in the domain (MD).
ma-name: Enters a VLAN ID, a descriptive name or a 2-
octet integer for the MA.
Note: If you set the format to vid, the VLAN
ID should be the same as the VLAN ID
you use to identify the MA.
C13
cc-interval
<100ms|1s|10s|1min|10min>
Sets how often an MEP sends a connectivity check
message (CCM).
C13
mhf-creation < none | default |
explicit>
Sets MHF (MIP Half Function).
Select none and no MIP can be created automatically for
this MA.
Select default to automatically create MIPs for this MA
and on the ports belonging to this MA’s VLAN when there
are no lower configured MD levels or there is an MEP at
the next lower configured MD level on the port.
Select explicit to automatically create MIPs for this
MA and on the ports belonging to this MA’s VLAN only
when there is an MEP at the next lower configured MD
level on the port.
C13
id-permission < none | chassis
| management | chassis-
management>
Sets what’s to be included in the sender ID TLV (Type-
Length-Value) transmitted by CFM packets.
Select none to not include the sender ID TLV.
Select chassis to include the chassis information.
Select management to include the management
information.
Select chassis-management to include both chassis
and management information.
C13
exit Exits from the config-ma mode. C 13
remote-mep <mep-id> Sets a remote MEP in an MA. C 13
mep <mep-id> interface port-
channel <port> direction
<up|down> priority <0-7>
Sets an MEP in an MA.
up|down: The traffic direction.
0-7: The priority value of the CCMs or LTMs transmitted
by the MEP. 1 is the lowest, then 2, 0 and 3 ~ 7.
C13
mep <mep-id> interface port-
channel <port> direction
<up|down> priority <0-7>
inactive
Disables a specified MEP. C 13
mep <mep-id> interface port-
channel <port> direction
<up|down> priority <0-7> cc-
enable
Enables Connectivity Check (CC) to allow an MEP
sending Connectivity Check Messages (CCMs)
periodically to other MEPs.
C13
no remote-mep <mep-id> Deletes a specified destination MEP. C 13
no mep <mep-id> Deletes a specified MEP. C 13
no mep <mep-id> inactive Enables an MEP. C 13
no mep <mep-id> cc-enable Disallows an MEP sending Connectivity Check
Messages (CCMs) periodically to other MEPs.
C13
Table 29 CFM Command Summary (continued)