Delta Electronics DVP10MC11T [182/375] Motion control instruction

Delta Electronics DVP10MC11T [182/375] Motion control instruction
4. Motion Control Instruction
4-138 DVP-MC operating manual
4.6.35. MOVB
API
MOVB
Move multiple register data to the
target registers
Controller
162
10MC11T
Explanation of the instruction:
MOVB is used for sending multiple source register values to the corresponding multiple target registers.
When EN is on, the zone data with S1 as the starting register data is sent to the zone with D as the starting
register and the data length is specified by S2. When the data length S2 is larger than maximum 64, it is
counted as 64. And the part above 64 is invalid.
Explanation of input and output parameter of the instruction:
Parameter
name
Explanation
Data
type
Available
device
EN “MOVB” is executed as “EN” turns on. BOOL M,I,Q, constant
S1
The starting register of the source zone where the data
comes from.
INT D
S2
The length of the transmitted zone, the max value for S2
is 64.
UINT Constant,D
D The starting register of the target zone INT D
Program example