Delta Electronics DVP10MC11T [19/375] System function

Delta Electronics DVP10MC11T [19/375] System function
2. System Function
DVP-MC operating manual 2-11
Special
D
Function explanation Attribute Data type Latched Remark
D6516
Communication ID
and communication
format of
DVP10MC11T
R/W UINT Y
b3~b0=0000: 7,E,1,ASCII
b3~b0=0001: 7,O,1,ASCII
b3~b0=0010: 7,N,1,ASCII
b3~b0=0100: 8,N,2,RTU
b7~b4=0000: 9600bps
b7~b4=0001: 19200bps
b7~b4=0010: 38400bps
b7~b4=0011: 57600bps
b7~b4=0100: 115200bps
b15~b8 are used to set the
Modbus node ID, e.g.
b15~b8=00000001which
indicates that Modbus node ID
is 1, likewise other Modbus
node ID are named in the
same way. Note: b stands for
bit.
D6517
Current scan time for
logic program
Unit: us
R UINT N
The time needed for the logic
program to carry out scanning
currently.
D6518
Max. scan time for
logic program
Unit: us
R UINT N
The maximum time needed for
the logic program to scan one
time.
D6519
Setting of the
quantity of D device
in the latched area
R/W UINT Y
The start D device in the
latched area is D7000; the
quantity is specified by D6519;
range: 0~3000.
D6520
Setting of the
quantity of M device
in the latched area
R/W UINT Y
The start M device in the
latched area is M3000; the
quantity is specified by D6520;
range: 0~1000
D6527
The pulse number
that servo motor
feeds back to servo
drive
R DINT N
When DMC_ CapturePosition
is used for position capture in
mode 1, the value of D6527 is
the pulse number that servo
motor feeds back to servo
drive.
D6529
The pulse number
received at the
interface of the
encoder
R DINT N
When DMC_ CapturePosition
uses I0 for position capture in
mode 10, the value of D6529
is the pulse number received
at the interface of the encoder
of 10MC.