Delta Electronics DVP10MC11T [336/375] Appendix c

Delta Electronics DVP10MC11T [336/375] Appendix c
Appendix C
DVP-MC operating manual C-15
Special registers related with axis 8
Special
D
Modbus
address
HEX
Function Range Type Latched Attribute
D26368 E700
Type0: rotary 1: linear
0-1 UINT No Read only
D26369 E701
Modulo
-- DINT
No Read only
D26370 E702 No Read only
D26371 E703
Acceleration and deceleration
type0:T 1: S 2:JERK
0-2 UINT No Read only
D26372 E704
Numerator of electronic gear
0 - 65535 UINT No Read only
D26373 E705
Denominator of electronic gear
0 - 65535 UINT No Read only
D26374 E706
Software limit0:disable,
1:enable
0-1 UINT No Read only
D26375 E707
The positive position limit
--
DINT
No Read only
D26376 E708 -- No Read only
D26377 E709
The negative position limit
--
DINT
No Read only
D26378 E70A -- No Read only
D26379 E70B
Homing mode; please refer to
appendix D
1-35 UINT No Read only
D26380 E70C
Homing speed
(Unit: r/min)
--
UDINT
No Read only
D26381 E70D -- No Read only
D26382 E70E
Maximum speed
Unit: unit/ second
--
UDINT
No Read only
D26383 E70F -- No Read only
D26384 E710
Maximum acceleration
Unit: unit/ second
2
--
UDINT
No Read only
D26385 E711 -- No Read only
D26386 E712
Maximum deceleration
Unit: unit/ second
2
--
DINT
No Read only
D26387 E713 -- No Read only
D26388 E714
Given positionUnit: pulse
--
DINT
No Read only
D26389 E715 -- No Read only
D26390 E716
Given speed
(Unit: pulse/second
--
DINT
No Read only
D26391 E717 -- No Read only
D26392 E718
Given acceleration
Pulse/second
2
--
DINT
No Read only
D26393 E719 -- No Read only
D26394 E71A
Current position (Unit: pulse)
--
DINT
No Read only
D26395 E71B -- No Read only
D26396 E71C
Current position error (Unit:
pulse)
--
DINT
No Read only
D26397 E71D -- No Read only
D26398 E71E
Axis current state (See section
4.2
UINT No Read only
D26405 E725
Unit number per turn
--
DINT
No Read only
D26406 E726 -- No Read only
D26407 E727
The allowed position error
-- UINT No Read only