Daikin REYQ16PY1B [25/477] Sibe37 701_b specifications

Daikin REYQ16PY1B [25/477] Sibe37 701_b specifications
SiBE37-701_B Specifications
Specifications 14
Notes:
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference : 0m.
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference : 0m.
3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level
difference : 0m.
Model Name (Combination Unit) REYQ22P7Y1B REYQ24P7Y1B
Model Name (Independent Unit) REMQ10P7Y1B+REMQ12P7Y1B REMQ12P7Y1B+REMQ12P7Y1B
1 Cooling Capacity (19.5°CWB)
kcal / h 53,200 58,000
Btu / h 211,000 230,000
kW 61.9 67.4
2 Cooling Capacity (19.0°CWB) kW 61.5 67.0
3 Heating Capacity
kcal / h 59,300 64,500
Btu / h 235,000 256,000
kW 69.0 75.0
Casing Color
Y1 Type Ivory White 5Y7.5/1 Ivory White 5Y7.5/1
Y1E Type Light Camel 2.5Y6.5/1.5 Light Camel 2.5Y6.5/1.5
Dimensions: (H×W×D) mm 1680×930×765+1680×930×765 1680×930×765+1680×930×765
Heat Exchanger Cross fin coil Cross fin coil
Comp.
Type Hermetically sealed scroll type Hermetically sealed scroll type
Piston Displacement m³/h (13.34+10.53)×2 (13.34+10.53)×2
Number of Revolutions r.p.m (6300, 2900)×2 (6300, 2900)×2
Motor Output×Number
of Units
kW (3.5+4.5)×1+(2.2+4.5)×1 (3.5+4.5)×2
Starting Method Soft start Soft start
Fan
Type Propellor fan Propellor fan
Motor Output kW (0.75×1)+(0.75×1) 0.75×2
Airflow Rate
I/s 3,083+3,333 3,333+3,333
m³/min 185+200 200+200
Drive Direct drive Direct drive
Connecting
Pipes
Liquid Pipe
φ
15.9 C1220T (Brazing connection)
φ
15.9 C1220T (Brazing connection)
Suction Gas Pipe
φ
28.6 C1220T (Brazing connection)
φ
34.9 C1220T (Brazing connection)
High and Low Pressure Gas Pipe
φ
28.6 C1220T (Brazing connection)
φ
28.6 C1220T (Brazing connection)
Pressure Equalizer Tube
φ
19.1 C1220T (Brazing connection)
φ
19.1 C1220T (Brazing connection)
Mass (Weight) kg 254+254 254+254
Safety Devices
High pressure switch, fan driver overload protector,
overcurrent relay, inverter overload protector
High pressure switch, fan driver overload protector,
overcurrent relay, inverter overload protector
Defrost Method Deicer Deicer
Capacity Control % 7~100 6~100
Refrigerant
Refrigerant Name R-410A R-410A
Charge kg 9.0+9.1 9.1+9.1
Control Electronic expansion valve Electronic expansion valve
Refrigerator Oil Refer to the nameplate of compressor Refer to the nameplate of compressor
Standard Accessories
Installation manual, Operation manual, Connection pipes,
Clamps
Installation manual, Operation manual, Connection pipes,
Clamps
Drawing No. C: 4D057570A C: 4D057571A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3

Содержание

Скачать