Daikin REYQ16PY1B [427/477] Indoor unit

Daikin REYQ16PY1B [427/477] Indoor unit
SiBE37-701_B Wiring Diagrams for Reference
Appendix 416
2.3 Indoor Unit
FXFQ20P / 25P / 32P / 40P / 50P / 63P / 80P / 100P / 125P8VEB
,
Indoor unit
R2T Thermistor (coil) SS1 Selector switch (main/sub)
A1P Printed circuit board R3T Thermistor (header) SS2
Selector switch (Wireless address set)
A2P Printed circuit board S1L Float Switch
Connector for optional parts
C1 Capacitor X1M Terminal strip X24A Connector (Wireless remote control)
F1U Fuse (T, 5A, 250V) X2M Terminal strip X33A Connector (Adaptor for wiring)
F2U Field fuse Y1E Electronic expansion valve X35A Connector (Group control adaptor)
HAP
Light emitting diode (service motor green)
Z1C Ferrite core X38A Connector (Multi tenant)
KPR Magnetic relay (M1P)
Receiver/display unit (attached to wireless remote control)
Wired remote control
L1 Coil A3P Printed circuit board R1T Thermistor (air)
M1F Motor fan (indoor fan) A4P Printed circuit board SS1 Selector switch (main/sub)
M1P Motor fan (drain pump) BS1 Push button (on/off)
M1S Motor (swing flap) H1P Light emitting diode (on-red)
PS Power supply circuit H2P Light emitting diode (timer-green)
O1DI Earth leak detector H3P Light emitting diode (filter sign-red)
R1T Thermistor (air) H4P Light emitting diode (defrost-orange)
: Terminal
: Connector
: Connector
: Field wiring
Colors: RED: Red PRP: Purple ORG: Orange
: Connector
BLK: Black GRY: Gray GRN: Green
WHT:White Blu: Blue
YLW: Yellow PNK: Pink
NOTES
1 In case of using central remote control, connect it to the unit in accordance with the attached installation manual.
2 X24A, X33A, X35A en X38A are connected when the optional accessories are being used.
3 When connecting the input wires from outside, forced of on/off control operation can be selected by the remote controller.
see installation manual for more details.
4 Confirm the method of setting the selector switch (SS1, SS2) by installation manual and engineering data, etc.
3TW31056-1
20~125-CLASS
X24A
A1P
X1M
X2M
X35A
X33A
Control box
A2P
H05VV-U3G2.5
F2U
Q1DI
220~240/220V
~50/60Hz
Indoor
RED
BLU
X2M
GRN/YLW
X20A
Z1C
N=1
WHT
ORG
BRN
BLU
RED
M1F
MS
3~
20~63-CLASS
(22~71-CLASS)
X20A
Z1C
N=1
WHT
ORG
BRN
BLU
RED
M1F
MS
3~
80~125-CLASS
(90~140-CLASS)
A1P
X27A
F1U
KPR
X25A
PS
M1P
M
~
YLW
YLW
GRN
R3T R2T
X17A X18AX15A
S1L
X24A
X30A
X36A
HAP
X35AX33A
X16A
X7A
M
X38A
CN1
A2P
PNK
WHT
YLW
ORG
BLU
BLK
X1M
T2
T1
F2
F1
P2
P1
MSW
M1S
A3P A4P
SS1
SS2
X2A
H1P
H2P
H3P
H4P
BS1
Receiver/Display unit
Input from outside (Note 3)
Central remote controller
(note 1)
Wired remote
controller
P1
P2
R1T
SS1
LL
N
L
N
X1A X1A
R1T
Y1E

Содержание