Daikin REYQ16PY1B [465/477] Diode module checking

Daikin REYQ16PY1B [465/477] Diode module checking
SiBE37-701_B Method of Checking the Inverter’s Power Transistors and Diode Modules
Appendix 454
1. Power module checking
2. Diode module checking
When using the analog type of multiple
tester, make measurement in resistance
measurement mode in the x1k
range.
When using the digital type of multiple
tester, make measurement in diode check
mode ( ).
No.
Measuring
point
Criterion Remark No.
Measuring
point
Criterion Remark
+- +-
1P3U
2 to 15k
1P3U
Not less
than 1.2V
(including)
It may take time to
determine the voltage
due to capacitor
charge or else.
2P3V 2P3V
3P3W 3P3W
4UP3
Not less
than 15k
(including)
It may take
time to
determine the
resistance due
to capacitor
charge or else.
4UP3
0.3 to 0.7V
5VP3 5VP3
6 W P3 6 W P3
7N3U 7N3U
8N3V 8N3V
9N3W 9N3W
10 U N3
2 to 15k
10 U N3
Not less
than 1.2V
(including)
It may take time to
determine the voltage
due to capacitor
charge or else.
11 V N3 11 V N3
12 W N3 12 W N3
When using the analog type of multiple
tester, make measurement in resistance
measurement mode in the x1k
range.
When using the digital type of multiple
tester, make measurement in diode check
mode ( ).
No.
Measuring
point
Criterion Remark No.
Measuring
point
Criterion Remark
+- +-
1P1J1
2 to 15k
1P1J1
Not less
than 1.2V
(including)
It may take time to
determine the voltage
due to capacitor
charge or else.
2P1J2 2P1J2
3P1J3 3P1J3
4J1P1
Not less
than 15k
(including)
It may take
time to
determine the
resistance due
to capacitor
charge or else.
4J1P1
0.3 to 0.7V
5J2P1 5J2P1
6J3P1 6J3P1
7N3J1 7N3J1
8N3J2 8N3J2
9N3J3 9N3J3
10 J1 N3
2 to 15k
10 J1 N3
Not less
than 1.2V
(including)
It may take time to
determine the voltage
due to capacitor
charge or else.
11 J2 N3 11 J2 N3
12 J3 N3 12 J3 N3

Содержание