Moxa ioLogik E2210 [169/263] Iologik e2200 series cgi commands

Moxa ioLogik E2240-T [169/263] Iologik e2200 series cgi commands
ioLogik E2200 Series CGI Commands
G-24
DOLowWidth_02 DOLowWidth_03
DOHighWidth_02 DOHighWidth_03
DOPulseStart_02
(0:STOP, 1:START)
DOPulseStart_03
(0:STOP, 1:START)
Syntax to get the settings is as follows. Starting with the ioLogik’s IP or URL, specify setParam.cgi with a
question mark. Then specify the command with another question mark as the ending. Those commands are
case sensitive and the & sign is used to combine multiple commands.
Commands to set TC channels Commands to set TC channels
TcEnable_00
(0:Disable, 1:Enable)
TcEnable_01
(0:Disable, 1:Enable)
TcStype_00
(0:J, 1:K, 2:T, 3:E, 4:R, 5:S, 6:B, 7:N Type and
8:78.126mV, 9:39.062mV, 10:19.532mV)
TcStype_01
(0:J, 1:K, 2:T, 3:E, 4:R, 5:S, 6:B, 7:N Type and
8:78.126mV, 9:39.062mV, 10:19.532mV)
TcUtype_00
(Unit Types. 0:°C, 1:°F, 2:mV)
TcUtype_01
(Unit Types. 0:°C, 1:°F, 2:mV)
TcEnable_02
(0:Disable, 1:Enable)
TcEnable_03
(0:Disable, 1:Enable)
TcStype_02
(0:J, 1:K, 2:T, 3:E, 4:R, 5:S, 6:B, 7:N Type and
8:78.126mV, 9:39.062mV, 10:19.532mV)
TcStype_03
(0:J, 1:K, 2:T, 3:E, 4:R, 5:S, 6:B, 7:N Type and
8:78.126mV, 9:39.062mV, 10:19.532mV)
TcUtype_02
(Unit Types. 0:°C, 1:°F, 2:mV)
TcUtype_03
(Unit Types. 0:°C, 1:°F, 2:mV)
TcEnable_04
(0:Disable, 1:Enable)
TcEnable_05
(0:Disable, 1:Enable)
TcStype_04
(0:J, 1:K, 2:T, 3:E, 4:R, 5:S, 6:B, 7:N Type and
8:78.126mV, 9:39.062mV, 10:19.532mV)
TcStype_05
(0:J, 1:K, 2:T, 3:E, 4:R, 5:S, 6:B, 7:N Type and
8:78.126mV, 9:39.062mV, 10:19.532mV)
TcUtype_04
(Unit Types. 0:°C, 1:°F, 2:mV)
TcUtype_05
(Unit Types. 0:°C, 1:°F, 2:mV)
TcEnable_06
(0:Disable, 1:Enable)
TcEnable_07
(0:Disable, 1:Enable)
TcStype_06
(0:J, 1:K, 2:T, 3:E, 4:R, 5:S, 6:B, 7:N Type and
8:78.126mV, 9:39.062mV, 10:19.532mV)
TcStype_07
(0:J, 1:K, 2:T, 3:E, 4:R, 5:S, 6:B, 7:N Type and
8:78.126mV, 9:39.062mV, 10:19.532mV)
TcUtype_06
(Unit Types. 0:°C, 1:°F, 2:mV)
TcUtype_07
(Unit Types. 0:°C, 1:°F, 2:mV)
Commands to set TC Virtual channels Commands to set TC Virtual channels
TcStype_08
(20: Average, 21: Difference)
TcStype_09
(20: Average, 21: Difference)
TcUtype_08
(Unit Types. 0:°C, 1:°F, 2:mV)
TcUtype_09
(Unit Types. 0:°C, 1:°F, 2:mV)
TcStype_10
(20: Average, 21: Difference)
TcStype_11
(20: Average, 21: Difference)
TcUtype_10
(Unit Types. 0:°C, 1:°F, 2:mV)
TcUtype_11
(Unit Types. 0:°C, 1:°F, 2:mV)
TcStype_12
(20: Average, 21: Difference)
TcStype_13
(20: Average, 21: Difference)
TcUtype_12
(Unit Types. 0:°C, 1:°F, 2:mV)
TcUtype_13
(Unit Types. 0:°C, 1:°F, 2:mV)
TcStype_14
(20: Average, 21: Difference)
TcStype_15
(20: Average, 21: Difference)