INSPECTION AND REPAIR Intake and Exhaust Cam Lobe 35 75 35 85 mm mm 1 407 1 411 in Cam Lobe 27 998 28 098 mm 1 102 1 106 in Camshaft Cap Clearance Measurement 1 Install Camshaft 2 Position Strip of Plastigage YU 33210 onto camshaft A For Exhaust B For Intake 3 Install Camshaft caps 4 Tighten Camshaft cap bolts Camshaft Cap Bolt 10 Nm 1 0 mkg 7 2 ft lb NOTE ___________ Do not turn the camshaft when measuring clearance with plastigage 5 Measure Camshaft caps 6 Measure Width of Plastigage T Out of specification Follow step 7 Camshaft to cap Clearance Standard 0 020 0 054 mm 0 0008 0 0021 in Maximum 0 150mm 0 006in 3 26