Yamaha F115 AETL [362/709] Water pump counter rotation models
6-31
E
LOWR
WATER PUMP (COUNTER ROTATION MODELS)
CHECKING THE IMPELLER HOUSING 6
Check:
Impeller housing
Cracks/damage Replace.
CHECKING THE IMPELLER AND
IMPELLER HOUSING CUP
6
Check:
Impeller
Impeller housing cup
Cracks/damage Replace any defec-
tive parts.
CHECKING THE WOODRUFF KEY 6
Check:
Woodruff key
Damage/wear Replace.
INSTALLING THE IMPELLER AND
IMPELLER HOUSING
6
1. Install:
Washers 1
Wave washer 2
Spacer 3
Collar 4
NOTE:
The collar and spacer should fit together
firmly.
While pulling the drive shaft up, install the
collar with some appropriate tool a that
fits over the drive shaft as shown.
2. Install:
O-ring 1
Impeller housing cup 2
Impeller housing 3
O-ring 4
NOTE:
When installing the impeller housing cup,
align its projection with the hole in the
impeller housing.
When installing the water pump housing,
turn the drive shaft clockwise.
6050