Grundfos MAGNA3 D 32-80 180 97924451 [17/1656] Glycol

Grundfos MAGNA3 D 32-80 180 97924451 [17/1656] Glycol
English (GB)
17
6.2.1 Glycol
You can use the pump for pumping water-ethylene-glycol
mixtures up to 50 %.
Example of a water-ethylene-glycol mixture:
Maximum viscosity: 50 cSt ~ 50 % water / 50 % ethylene-glycol
mixture at -10 °C.
The pump has a power-limiting function that protects it against
overload.
The pumping of water-ethylene-glycol mixtures affects the
maximum curve and reduces the performance, depending on the
water-ethylene-glycol mixture and the liquid temperature.
To prevent the ethylene-glycol mixture from degrading, avoid
temperatures exceeding the rated liquid temperature and
minimise the operating time at high temperatures.
Clean and flush the system before you add the ethylene-glycol
mixture.
To prevent corrosion or lime precipitation, check and maintain the
ethylene-glycol mixture regularly. If further dilution of the supplied
ethylene-glycol is required, follow the glycol supplier's
instructions.
Fig. 19 Pumped liquids, threaded version
6.3 Identification
6.3.1 Nameplate
Fig. 20 Example of nameplate
* Example of production code: 1326. The pump was produced in
week 26, 2013.
Fig. 21 Production code on packaging
Additives with a density and/or kinematic viscosity
higher than those/that of water reduce the hydraulic
performance
TM05 8457 2313
TM05 5981 4312
Pos. Description
1Product name
2 Model
3 Production code, PC, year and week*
4 Serial number
5 Product number
6 Country of manufacture
7 Enclosure class
8 Energy Efficiency Index, EEI
9 Part, according to EEI
10 Temperature class
11 Minimum current [A]
12 Maximum current [A]
13 Minimum power [W]
14 Maximum power [W]
15 Maximum system pressure
16 Voltage [V] and frequency [Hz]
17 QR code
18 CE mark and approvals
19 Manufacturer's name and address
TM06 6692 3216